Write your message
Volume 13, Issue 4 (Iranian Journal of Breast Disease 2021)                   ijbd 2021, 13(4): 33-39 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jafar Aghaei M, Sajjadi H, Dehghani Zahedani M, Banihashemi S H, Booshehri E. Comparing Sensitivity and Specificity of Liquid-Based and Conventional Cytology Smears in Fine Needle Aspirates for Diagnosis of Breast Mass. ijbd 2021; 13 (4) :33-39
URL: http://ijbd.ir/article-1-842-en.html
1- Department of Pathology, Faculty of Medicine, Hormozgan University of Medical Sciences, Bandar Abbas, Iran
2- Department of Pathology, Faculty of Medicine, Hormozgan University of Medical Sciences, Bandar Abbas, Iran , sajjadipathologyh@gmail.com
3- Department of Surgery, Faculty of Medicine, Hormozgan University of Medical Sciences, Bandar Abbas, Iran
4- Department of Public Health, Health School, Hormozgan University of Medical Science, Bandar Abbas, Iran
Abstract:   (2455 Views)

Introduction: This study aimed to compare the cytology results obtained by the conventional smear method with those obtained by the liquid-based method for the diagnosis of palpable breast masses in women referred to the clinic of Shahid Mohammadi Hospital in Bandar Abbas city.
Methods: The research method was descriptive–cross-sectional. The research sample was selected based on purposive and availability sampling. Accordingly, 67 patients referred to the surgical clinic of Shahid Mohammadi Hospital in 2019-2020 were evaluated. The diagnostic sensitivity, diagnostic specificity, positive predictive value, and negative predictive value of conventional smear method and liquid-based method were compared.
Results: The diagnostic sensitivity of the conventional smear method was 88.4%, specificity 94.9%, positive predictive value 92%, and negative predictive value 92.5%. The diagnostic sensitivity of the liquid-based method was 84%, specificity 90%, positive predictive value 80.7%, and negative predictive value 90%.
Conclusion: Liquid-based method is better than conventional smear because of the ease of processing, faster screening, and preservation of cells and nuclear details. And it can be a promising and reliable method to diagnose palpable breast masses before surgery.

Full-Text [PDF 557 kb]   (1108 Downloads)    
Conclusion: Liquid-based method is better than conventional smear because of the ease of processing, faster screening, and preservation of cells and nuclear details. And it can be a promising and reliable method to diagnose palpable breast masses before surgery.

Type of Study: Research |
Received: 2020/09/21 | Accepted: 2020/11/30 | Published: 2021/02/19

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Iranian Journal of Breast Diseases